Friday, February 10, 2012 :: An Applied Technology Publication
image image image image
A Real-World Approach To Improved Lubrication, Part One This practical series examines proven strategies and tactics from an equipment standpoint, one system at a time. Read the Full Story
Extending The Life Of Gear Reducers Dip into these tips to get your lube practices up to speed. Read the Full Story
Anatomy Of A CLS: Single-Point Lubricator Technology These workhorses (aka SPLs) may not be right for every application, but they have a rightful place in every plant’s lube-management program. Read the Full Story
Get It Right: Respect The 5Rs Refreshing yourself and your team on the “RIGHTS” of lubrication can help prevent plenty of lubrication “WRONGS” around your operations. Read the Full Story

Calculating True Motor Efficiency

1023livotimugThe Energy Independence Security Act of 2007 (EISA) becomes law December 19, 2010. A portion of EISA covers induction motors from 1-500 hp. It's safe to say most end users will be affected.

What does EISA have to do with calculating true motor efficiency? More than you would think. At some point, you'll need to replace a motor covered by EISA. Replacing it with a duplicate that meets the new law would seem to make perfect sense. Not so fast! Before rushing a purchase order through, take time to determine:

  • Motor efficiency versus nameplate
  • Motor efficiency versus load

To clarify: Yes, you'll improve overall efficiency around two efficiency points by replacing a standard efficient motor with a new EISA premium efficient model. There's much more to be gained, however, by making a few calculations.

Facts
Motor nameplate data doesn't identify precise motor efficiency—only a range as defined by NEMA. An induction motor is highly efficient when operating close to its rated torque and speed, but it still has five major components of loss: iron loss, copper loss, frictional loss, windage loss and sound loss. Together, they add up to the total loss of the motor.

Frictional, windage and sound losses are constant, independent of shaft load and typically very small. The major losses are from iron and copper. Iron loss is essentially constant and independent of shaft load, while copper represents a I2R loss, which is shaft-load dependent. Since iron loss is voltage-dependent, it will reduce with reducing voltage.

Most electric motors are designed to run at 50% to 100% of rated load, with maximum efficiency usually near 75%. Thus, a 10 hp motor has an acceptable load range of 5 hp to 10 hp, with peak efficiency at 7.5 hp. Motor efficiency tends to decrease dramatically below about 50% load. The range of good efficiency, however, varies with individual motors and tends to extend over a broader range for larger units. A motor is considered under-loaded when it's in the range where efficiency drops significantly with decreasing load. Throw in a poor motor rewind, and you could have a far-less-efficient motor than the nameplate data indicates.

It is also a well-known fact that motor pumping systems (most pumps are motor-driven) operate at less than 40% efficiency. Clearly, there's an opportunity to save additional energy by reducing the size of the motor.

Calculating
Keep these points in mind when you set out to calculate true motor efficiency:

  • Use power, amperage or slip measurements to identify the load imposed on the operating motor.
  • Obtain a motor part-load efficiency value consistent with the approximated load from the manufacturer. Or, if direct-read power measurements are available, derive a revised load estimate using both the power measurement at the motor terminals and the part-load efficiency.

Help
If your company tracks energy savings and justifies projects based on documented payback, evaluating your motor performance/load is important. Help is out there. Several commercially available devices will do these calculations for you. If you don't have the resources within your plant to make the calculations, contact a local EASA (Electrical Apparatus Service Association) shop that offers
this service. UM


Bill Livoti is a fluid power and power industry engineer with Baldor Electric Company. Telephone: (864) 281-2118; e-mail: This e-mail address is being protected from spambots. You need JavaScript enabled to view it

Problem Solvers

Latest Product

Fast, No-Hassle, CMMS "Toolbox"

Fast, No-Hassle, CMMS "Toolbox"

Fast, No-Hassle, CMMS "Toolbox" MAPCON's On-Demand™ uses cutting-edge SaaS (software-as-a-service) technology to provide companies with comprehensive maintenance management (including work orders and preventive maintenance scheduling tools). According to the manufacturer, On-Demand is delivered "blazingly fast" and economically over the Internet to customer computers, eliminating slowdown that can be associated with using browsers to access information. The application is billed month-to-month, with no contract periods or penalties for upgrades or downgrades. As a standard policy, MAPCON offers...

Read More...

Product Solutions For Companies Going Green

Product Solutions For Companies Going Green

For 83 years, Grainger has been serving businesses and institutions across a variety of industries by helping them save time and money related to their maintenance, repair and operating supplies needs. Today, the company remains committed to listening to its customers and helping to collaboratively find the most cost-effective solutions for their evolving business needs.

Read More...

Compression Packing Technical Manual 3rd Edition

Compression Packing Technical Manual 3rd Edition

Available in both a printed version and on a CD, is the latest technical publication from the Fluid Sealing Association (FSA). In its 3rd printing, this popular manual offers a highly practical set of guidelines for the use of compression packings to control fluid loss in mechanical, fluid-handling equipment.

Read More...

Expanded Worm Gear Line

Expanded Worm Gear Line

Expanded Worm Gear Line Baldor has expanded its Dodge ULTRA KLEEN right-angle, worm gear reducer line and is now offering 24- to 48-hour shipment on most sizes.

Read More...

Download Issue

January/February 2012 Issue
Lubrication Management & Technology
0102cover

Free Subscriptions

lmt_enewsSign up for the Lubrication Management & Technology bi-monthly eNewsletter and instantly receive the most recent feature articles, columns, news and products in your inbox.

Subscribe Today!

lmt3409covLubrication Management & Technology, the magazine for achieving efficiencies through practices and products, serves the business and technical information needs of engineers, managers, and technicians who design, troubleshoot and maintain lubrication and fluid power systems and buy and specify lubricants and fluids.

Subscribe today!

Webinars

Finding the Hidden Teachers in Your Organization
sponsored by Life Cycle Engineering

Solutions To NFPA 70E Adherence & Arc Flash Safety
sponsored by Mikron Infrared

Arc Flash Avoidance And NFPA 70E Compliance
sponsored by Mikron Infrared